ACLW-RS
Parameter
Chlorophyll
Turbidity
Temperature
Sensor Type Fluorescent scattering light Infrared back-scattering method Thermistor
Measuring range 0.1 to 400 µg/l 0 to 1000FTU -5 to 40 XC
Resolution 0.01 µg/l 0.03FTU 0.001 XC
Accuracy 1 % 2 % 0.05 XC
A/D conversion 16-bit digital conversion
Depth rating 200m
ADOW-RS
Parameter
DO
Temperature
Sensor Type Galvanic cell Thermistor
Measuring range 0 to 200 % -5 to 40 XC
Resolution 0.005 % 0.001 XC
Accuracy 1% 0.05 XC
A/D conversion 16-bit digital conversion
Depth rating 200 m
AEM-RS
Parameter
Current speed
Current direction
Temperature
Sensor Type 2-axis electro-magnetic sensor
Hall element compass
Thermistor
Measuring range 0 to 500 cm/s 0 to 360 X -5 to 40 XC
Resolution 0.02 cm/s 0.01 X 0.001 XC
Accuracy 1 cm/s or 2 % 2 X 0.05 XC
A/D conversion 16-bit digital conversion
Depth rating 1000 m
ACT-RS
Parameter
Temperature
Conductivity
Sensor Type Thermistor Inductive cell
Measuring range -5 to 40 XC 0 to 60 mS/cm
Resolution 0.001 XC 0.001 mS/cm
Accuracy 0.05 XC 0.05 mS/cm
A/D conversion 16-bit digital conversion
Depth rating 200 m
AWH-RS
Parameter Wave height
Sensor Type
Semi-conductor sensor
Measuring range 0 to 25 m
Resolution 1 mm
Accuracy 0.3 %
A/D conversion 16-bit digital conversion
Depth rating 25 m
ALW-RS
Parameter
Photo quantum
Sensor Type
Photo Diode
Measuring range 0 to 5000 µmol/m²
Resolution 0.1 µmol/m²
A/D conversion 16-bit digital conversion
Depth rating 200 m